White Roller Coated Corrugated Board
It is made of high-quality aluminum plate lamination, and the surface layer is sprayed and roller coated.
It has excellent weight, strength, earthquake resistance and other effects, and has good weather resistance and corrosion resistance. The double-layer lamination process can ensure good surface smoothness.
Fireproof and high-temperature resistant, with excellent fireproof performance, effective high-temperature resistance, wide range of application scenarios, and long-term use that is not easy to change.
Inorganic Core Material Is Green And Environmentally Friendly
Good Fire Prevention And Fire Safety Performance
Installation Is Fast And Very Smooth And Clean
Lightweight Sound Insulation And Heat Insulation
Test items | Standard requirement | Test result | Single conclusion | According to the standard | |
Combustion performance level A (A2-s1, d0, t0) | Calorific value of main components (aluminum plate) | ≤3.0MJ/kg | 0MJ/kg | Conform to | GB/T 14402-2007 |
Calorific value of main components (aluminum honeycomb) | ≤3.0MJ/kg | 0MJ/kg | Conform to | ||
Calorific value of external secondary components (coating) | ≤4.0MJ/㎡ | 0.8MJ/㎡ | Conform to | ||
Calorific value of internal secondary components (resin glue) | ≤4.0MJ/㎡ | 3MJ/㎡ | Conform to | ||
Total heat of combustion | ≤3.0MJ/kg | 1.5MJ/kg | Conform to | ||
Flame spreads laterally | Did not reach test long wing edge | Did not reach test long wing edge | Conform to | GB/T 20284-2006 | |
Total smoke production within 600 seconds | ≤50㎡ | 17m2 | Conform to | ||
Smoke generation rate index | ≤30m2/s2 | 2m2/s2 | Conform to | ||
Combustion drippings/particles | No burning droplets within 600s | Conform to | |||
Total heat release in 600s | ≤7.5MJ | 1.1MJ | Conform to | ||
Burning rate growth index (FIGRA0.2MJ) | ≤120W/s | 29W/s | Conform to | ||
Smoke toxicity | Achieve quasi-safety level ZA1 | Achieve quasi-safety level ZA1 | Conform to | GB/T 20285-2006 | |
Combustion sample installation instructions | 1. The specimen shall be installed in accordance with Article 5.2.2b) of GB/T20284-2006. | ||||
2. The back plate of the sample is a calcium silicate plate with a thickness of 12mm and a density of 800kg/m². | |||||
3. The fire-receiving surface of the sample is the decorative surface. |
Ten year ultra long waterproof lifespan and 97% recycling rate
Reduce carbon emissions by over 40% compared to traditional buildings
External noise level of 90 decibels can be reduced to below 40 decibels inside the cabin
Night sleep quality satisfaction increased by 52%, repurchase rate increased by 35%
Design
Further design of overseas project drawings
Customization
Product supply and customization
Logistic
Logistics and overseas customs clearance
Cultivate
Product training
Construction
Local construction delivery installation training
After-Sales
After-sales service guarantee